AFERA 5001 Test Fixtures & Test Systems Model: G-AFERA-5001

Peel Table Kinematics: AFERA 5001 requires a highly controlled 90° or 180° peel environment. Our precision peel tables utilize low-friction linear bearings to ensure that the UTM measures only adhesive resistance.

Type: Standards
Family ID: G50

Technical Specifications

Specification Value
Test Type Standards
Industry Standard AFERA 5001
Interface Description Optimized for TestResources Load Frames; universal adapters available for legacy systems.

Interface & Compatibility

Optimized for TestResources Load Frames; universal adapters available for legacy systems.

Expert Commentary

The Constant Angle Variable: Adhesive strength is inherently rate-sensitive and angle-sensitive. The AFERA 5001 fixture must maintain a constant peel angle throughout the entire stroke. If the substrate plate chatters or the linear bearing binds, the resulting data will show sawtooth peaks that are artifacts of friction rather than adhesive properties. Because the forces involved are often low (under 50N), the tare weight of the fixture must be precisely balanced to ensure the load cell operates in its most linear range.