Test Fixtures for ASTM C165 Model: G-ASTM-C165

Compressive of Insulation.

Standards
G223

Technical Specifications

Specification Value
Model G-ASTM-C165
Industry Std ASTM C165
Test Type Standards
Family Id G223
Compat Machine If GLUM
Interface Description Optimized for TestResources Load Frames; universal adapters available for legacy systems.
Fixture If Gender GLUF

Interface & Compatibility

Optimized for TestResources Load Frames; universal adapters available for legacy systems.

Expert Commentary

Standard Method for Measuring Compressive Properties of Thermal Insulations. These materials (mineral wool, expanded polystyrene) are highly nonlinear and compliant. The yield is typically defined at 10% deformation. The technical difficulty is Zero Point determination. Because the surface of insulation is often uneven, the first contact between the platen and the specimen is ambiguous. MTO’s software uses a Pre-load Threshold logic to automatically define the 0,0 coordinate of the stress-strain curve. We also recommend our High-Area compression platens (200 x 200 mm) to ensure a statistically representative volume of the material is tested. This standard is a door-opener for the building materials industry, where repeatability in R-value and structural support capacity is a major selling point for manufacturers.

Product CTA

Ready to Start Your Project

Name