Test Fixtures for ASTM C307 Model: G-ASTM-C307

Mortar/Grout Tensile.

Standards
G474

Technical Specifications

Specification Value
Model G-ASTM-C307
Industry Std ASTM C307
Test Type Standards
Family Id G474
Compat Machine If 16M
Interface Description 15.9mm Female Cup with 8mm Crosspin
Fixture If Gender 16F

Interface & Compatibility

15.9mm Female Cup with 8mm Crosspin

Expert Commentary

Tensile Strength of Chemical-Resistant Mortar and Grouts. This test uses Briquet or Dog-bone specimens. These materials are used in highly corrosive industrial floors and tanks. The engineering focus is on Grip Interface. Standard jaws would crush the brittle mortar heads. MTO’s C-Shaped briquet grips utilize a curved contact surface that matches the specimen geometry exactly. This ensures that the stress is concentrated in the 1-inch square neck of the specimen. For engineers, we emphasize our Corrosion-Resistant grip options (Stainless Steel or Nickel-Plated), as these specimens are often tested after being soaked in acids or solvents, which can ruin standard tool-steel fixtures.

Product CTA

Ready to Start Your Project