Test Fixtures for ASTM D1037 Model: G-ASTM-D1037-S14

Tension Perpendicular.

Standards
G1669

Technical Specifications

Specification Value
Model G-ASTM-D1037-S14
Industry Std ASTM D1037
Std Ref Number Section 14
Test Type Standards
Family Id G1669
Compat Machine If GLUM
Interface Description Optimized for TestResources Load Frames; universal adapters available for legacy systems.
Fixture If Gender GLUF

Interface & Compatibility

Optimized for TestResources Load Frames; universal adapters available for legacy systems.

Expert Commentary

Governs Direct Nail Withdrawal. This measures the force required to pull a nail straight out of the panel face or edge. The standard specifies a constant rate of withdrawal (1.5 mm/min). MTO provides a U-shaped withdrawal fixture that supports the panel while allowing the nail head to be gripped. The technical focus is on the rate of loading, as wood is a viscoelastic material; pulling too fast can result in an overestimation of the withdrawal strength due to the time-dependent nature of fiber friction.