Test Fixtures for ASTM D3330 Model: G-ASTM-D3330
Tape Peel (180 Degree).
Standards
G989
Technical Specifications
| Specification | Value |
|---|---|
| Model | G-ASTM-D3330 |
| Industry Std | ASTM D3330 |
| Test Type | Standards |
| Family Id | G989 |
| Compat Machine If | GLUM |
| Interface Description | Optimized for TestResources Load Frames; universal adapters available for legacy systems. |
| Fixture If Gender | GLUF |
Interface & Compatibility
Optimized for TestResources Load Frames; universal adapters available for legacy systems.
Expert Commentary
The umbrella standard for Peel Adhesion of Pressure-Sensitive Tape. It includes multiple methods (A through F). The core requirement is a constant 180-degree or 90-degree peel at 300 mm/min. MTO systems utilize high-resolution load cells (typically 50N to 250N) with a high sampling rate to capture the chatter or stick-slip behavior common in high-tack adhesives. Our software provides the Average Peel Force across the middle 50mm of the test, filtering out the initial spike at the start of the peel to provide repeatable quality control data for the packaging and electronics industries.