Test Fixtures for ASTM A720 Model: G-ASTM-A720

Copper Hydrogen Embrittlement.

Standards
G953

Technical Specifications

Specification Value
Model G-ASTM-A720
Industry Std ASTM A720
Test Type Standards
Family Id G953
Compat Machine If GLUM
Interface Description Optimized for TestResources Load Frames; universal adapters available for legacy systems.
Fixture If Gender GLUF

Interface & Compatibility

Optimized for TestResources Load Frames; universal adapters available for legacy systems.

Expert Commentary

Test method for Ductility of Nonoriented Electrical Steel. It involves a ductility fraction or a specific bend test. Because electrical steels are often thin and brittle, the test requires a specialized manual or motorized bender that can apply a 180∘ bend over a very small radius without inducing tensile failure, which would invalidate the ductility measurement.