Test Fixtures for ASTM A720 Model: G-ASTM-A720
Copper Hydrogen Embrittlement.
Standards
G953
Technical Specifications
| Specification | Value |
|---|---|
| Model | G-ASTM-A720 |
| Industry Std | ASTM A720 |
| Test Type | Standards |
| Family Id | G953 |
| Compat Machine If | GLUM |
| Interface Description | Optimized for TestResources Load Frames; universal adapters available for legacy systems. |
| Fixture If Gender | GLUF |
Interface & Compatibility
Optimized for TestResources Load Frames; universal adapters available for legacy systems.
Expert Commentary
Test method for Ductility of Nonoriented Electrical Steel. It involves a ductility fraction or a specific bend test. Because electrical steels are often thin and brittle, the test requires a specialized manual or motorized bender that can apply a 180∘ bend over a very small radius without inducing tensile failure, which would invalidate the ductility measurement.