Test Fixtures for ASTM C1399 Model: G-ASTM-C1399
Residual Strength (FRC).
Standards
G902
Technical Specifications
| Specification | Value |
|---|---|
| Model | G-ASTM-C1399 |
| Industry Std | ASTM C1399 |
| Test Type | Standards |
| Family Id | G902 |
| Compat Machine If | GLUM |
| Interface Description | Optimized for TestResources Load Frames; universal adapters available for legacy systems. |
| Fixture If Gender | GLUF |
Interface & Compatibility
Optimized for TestResources Load Frames; universal adapters available for legacy systems.
Expert Commentary
Determines the Average Residual-Strength of Fiber-Reinforced Concrete. This involves a 4-point bend test where a steel plate is used initially to control the crack. Once the concrete cracks, the plate is removed, and the fibers carry the load. This requires bumpless transfer of control within the UTM software to accurately measure the residual capacity.