Testing Products for ISO 6892-1
APP-ISO-6892
Application Insight:
Method B vs A: Method A (Strain Rate Control) is now the preferred way to minimize data scatter.
Compliant Hardware Solution
611-600-690
This machine has been validated to meet the specific requirements of this standard.
View Machine DetailsRegulatory & Test Details
| App Id | APP-ISO-6892 |
|---|---|
| App Standard | ISO 6892-1 |
| Standard Organization | ISO |
| Test Type | Tension |
| Material Type | Metals |
| Specimen Type | Round / Flat |
| Industry Type | Automotive, Steel |
| Min Force Kn | 10 |
| Max Force Kn | 500 |
| Min Spd Mm/m | na |
| Max Spd Mm/m | na |
| Expert Spd | 0.00007 to 0.008 Rate (s⁻¹) Method A (Closed Loop). |
| Mach Recommend | 611-600-690 |
| Pointer App Software | N-ISO-6892-1 |
| Pointer Fixture Family | G-ISO-6892-1 |
| Pointer Strain Family | E-ISO-6892-1 |
Implementation Commentary
ISO 6892-1 is very detailed regarding the r (plastic strain ratio) and n (strain hardening exponent) values.