ASTM A370 Test Guide: Tensile Testing for Metals
TensileAlways use an extensometer rated for high-velocity shocks, and remove it immediately after yield if testing to failure.
Browse validated testing configurations. Filter by regulatory standard, material type, or force requirements.
23 items found
Always use an extensometer rated for high-velocity shocks, and remove it immediately after yield if testing to failure.
Ensure the support and loading rollers are free to rotate and articulate to completely eliminate parasitic twist stresses.
Clean and prime the substrate blocks precisely according to the manufacturer’s spec to isolate true sealant engineering limits.
When performing the perpendicular tensile test, use a high-strength epoxy to bond the metal blocks uniformly across the fiber face.
Cure the bonded block assembly under a uniform dead-weight load to ensure a perfectly flat, parallel adhesive layer.
Always place the specified elastomer pads between the anvils and the panel to spread out high localized line loads.
Always apply the static bending load to the natural molded face of the panel, and cross-reference thickness variations down to…
Always apply the exact standard-specified pre-tension (typically 0.5 cN / tex) to remove structural slack before zeroing strain metrics.
Always track and document sheet extrusion direction; test samples in both longitudinal and transverse axes to chart directional variation.
Inspect specimens under a microscope post-test; you must verify that the failure was true interlaminar shear and not top-edge crushing.
Ensure both ends of compression rods are machined perfectly flat and parallel to within 0.025mm to avoid localized end-brooming.
Never use standard manual screw grips; vulcanized rubber narrows drastically under tension and requires self-adjusting pneumatic jaws.
Store and condition tape rolls at standard atmospheric limits for exactly 24 hours prior to slitting or testing to equalize…
Calibrate the precise initial distance between the roller axes using a solid reference spacer to guarantee an exact baseline loop…
Inspect the internal perimeter of the drilled hole under a microscope before testing; any evidence of fiber fraying or ply…
Set the support span precisely to standard depth configurations and verify loading noses are perfectly aligned at the third or…
Always measure real specimen cross-section thickness at 3 distinct points before clamping; do not rely on nominal molded values.
Meticulously measure the inner radius and thickness at the curved apex to ensure mathematical precision in out-of-plane stress conversions.
Note that ASTM D7264 dictates a 32:1 span-to-thickness ratio, which is twice the 16:1 ratio specified by the plastics standard…
Always apply a minimal, uniform pre-load (~0.5 cN / tex) prior to starting the test loop to eliminate structural slack…